Zone Red winged wire nut, heavy duty (P13) — Red winged twist-on wire connector.

What wires it takes

Pressure-type wire connector. Solid and/or stranded wire combinations:

  • 1 #6
  • 1 or 2 #8
  • 1 to 4 #10
  • 1 to 5 #12
  • 1 to 6 #14 or #16
  • 2 to 6 #18
  • 3 to 6 #20
  • 4 to 6 #22
  • 1 #6 with 1 #10
  • 1 #6 with 1 #10 with 1 #14
  • 1 #6 with 1 or 2 #12
  • 1 #6 with 1 #12 with 1 or 2 #14
  • 1 #6 with 2 #12 with 1 #18
  • 1 #6 with 2 #14 with 1 or 2 #16
  • 1 #8 with 1 or 2 #10
  • 1 #8 with 1 #10 with 1 or 2 #12 or #14
  • 1 #8 with 2 #10 with 1 #14
  • 1 #8 with 1 to 3 #12
  • 1 #8 with 2 #12 with 1 or 2 #14
  • 1 #8 with 1 to 4 #14
  • 1 #8 with 1 to 5 #16
  • 1 #10 with 1 to 4 #12
  • 1 #10 with 1 #12 with 1 to 4 #14, #16 or #18
  • 1 #10 with 2 #12 with 1 or 2 #14
  • 1 #10 with 2 #12 with 1 to 3 #16 or #18
  • 1 #10 with 3 #12 with 1 #14
  • 1 #10 with 1 to 5 #14, #16 or #18
  • 1 #10 with 1 #14 with 1 to 4 #16 or #18
  • 1 #10 with 2 #14 with 1 to 3 #16
  • 1 #10 with 1 #16 with 1 to 4 #18
  • 2 #10 with 1 #12 with 1 or 2 #14
  • 2 #10 with 1 #12 with 1 to 3 #16
  • 2 #10 with 1 to 3 #12 or #14
  • 2 #10 with 2 #12 with 1 #14
  • 2 #10 with 2 #12 with 1 or 2 #16 or #18
  • 2 #10 with 1 to 4 #16 or #18
  • 2 #10 with 2 #14 with 1 or 2 #16
  • 2 #10 with 1 #16 with 1 to 3 #18
  • 3 #10 with 1 #12
  • 3 #10 with 1 #12 with 1 #16 or #18
  • 3 #10 with 1 or 2 #14
  • 3 #10 with 1 #14 with 1 #16
  • 3 #10 with 1 #14 with 1 or 2 #18
  • 3 #10 with 1 to 3 #16 or #18
  • 3 #10 with 1 #16 with 1 or 2 #18
  • 1 #12 with 1 to 5 #14, #16 or #18
  • 1 #12 with 1 #14 with 1 to 3 #18
  • 1 #12 with 1 #16 with 1 to 3 #18
  • 1 or 2 #12 with 1 #14 with 1 to 3 #16
  • 1 or 2 #12 with 2 #14 with 1 or 2 #16
  • 2 #12 with 1 to 4 #14, #16 or #18
  • 2 #12 with 1 #14 or #16 with 1 to 3 #18
  • 3 #12 with 1 to 3 #14, #16 or #18
  • 3 #12 with 1 #14 with 1 or 2 #16 or #18
  • 3 #12 with 2 #14 with 1 #16
  • 3 #12 with 1 #16 with 1 or 2 #18
  • 4 #12 with 1 #14
  • 4 #12 with 1 #14 with 1 #16 or #18
  • 4 #12 with 1 or 2 #16
  • 4 #12 with 1 #16 with 1 #18
  • 1 #14 with 1 to 5 #16 or #18
  • 1 #14 with 1 #16 with 1 to 3 #18
  • 1 #14 with 1 to 5 #20 or #22
  • 2 #14 with 1 to 4 #16, #18, #20 or #22
  • 2 #14 with 1 #16 with 1 to 3 #18
  • 3 #14 with 1 to 3 #16, #18, #20 or #22
  • 3 #14 with 1 #16 with 1 or 2 #18
  • 4 #14 with 1 or 2 #16, #18, #20 or #22
  • 4 #14 with 1 #16 with 1 #18
  • 5 #14 with 1 #16 or #18
  • 1 #16 with 1 to 5 #18, #20 or #22
  • 1 #16 with 1 #18 with 1 to 3 #20 or #22
  • 1 or 2 #16 with 1 #20 with 1 or 2 #22
  • 1 #16 with 2 #20 with 1 or 2 #22
  • 2 #16 with 1 to 4 #18, #20 or #22
  • 2 #16 with 1 #18 with 1 to 3 #20 or #22
  • 2 #16 with 2 #20 with 1 or 2 #22
  • 3 #16 with 1 to 3 #18, #20 or #22
  • 3 #16 with 1 #18 with 1 or 2 #20 or #22
  • 3 #16 with 1 #20 with 1 or 2 #22
  • 4 #16 with 1 or 2 #18, #20 or #22
  • 4 #16 with 1 #18 with 1 #20 or #22
  • 4 #16 with 1 #20 with 1 #22
  • 5 #16 with 1 #18, #20 or #22
  • 1 #18 with 1 to 5 #20 or #22
  • 1 to 3 #18 with 1 #20 with 1 or 2 #22
  • 1 to 3 #18 with 2 #20 with 1 #22
  • 2 #18 with 1 to 4 #20 or #22
  • 3 #18 with 1 to 3 #20 or #22
  • 4 #18 with 1 or 2 #20 or #22
  • 5 #18 with 1 #20 or #22
  • 1 #20 with 2 to 5 #22
  • 2 #20 with 1 to 4 #22
  • 3 #20 with 1 to 3 #22
  • 4 #20 with 1 or 2 #22
  • 5 #20 with 1 #22

Check a wire mix in the connector picker →

How to install

  1. Turn off power before installing or removing connectors.
  2. Strip wires 5/8" (15.9 mm).
  3. Pre-twisting unnecessary, hold stripped wires together with ends even. Lead stranded wires slightly.
  4. Align any frayed strands or conductors.
  5. Push wires into connector and screw on until two twists are visible in wires.

Good for

  • Light fixtures
  • Outlets and switches
  • Ceiling fans
  • Junction-box splices and general home and repair wiring

Questions about the P13

What wire sizes does the P13 fit?

The P13 published wire range is 22–8 AWG.

What standard is the P13 listed to?

The P13 listing states UL 486C.

What conductors does the P13 take?

Copper to copper.

Does the P13 have a combination chart?

Yes. The exact combinations printed on the P13 box are shown on this page.